Lagoon Pump Inspection Log
A lagoon pump that runs poorly wastes hours and fuel, and one that fails during a wet spell leaves you stuck. This log records flow, run hours, leaks and wear so you can service the pump before it quits.
Why it matters
Pumps lose output slowly as impellers wear, screens clog and hoses age, and a label rate hides that. Measured flow gives you the real numbers for hauling and emergency plans. Lock out power and follow the manufacturer manual before touching any pump; never enter pits or wet wells.
Step by step
- Write the make, model, serial number, rated flow and motor or engine type on the first page, copying from the plate on the pump.
- Before each season, check shaft seals, couplings, guards, hoses, clamps, and cables, with power locked out and the pump isolated.
- Time how long the pump takes to fill a tanker or tank of known volume, and divide gallons by minutes to get measured flow.
- Compare the measured flow with the rating as a percent, and note intake screen condition, noise, vibration and any leaks.
- Record the hour meter reading and compare it with the manufacturer service interval for grease, oil and bearing checks.
- Mark anything below your repair trigger, such as 80 percent of rating, and book the service before the next major pumping job.
Worked example
Illustrative: The pump is rated at 1,000 gallons per minute. It fills a 6,000-gallon tanker in 7.5 minutes, so measured flow is 6,000 / 7.5 = 800 gallons per minute, which is 800 / 1,000 = 80 percent of rating. A 500,000-gallon pump-out then takes 500,000 / 800 = 625 minutes, about 10.4 hours. At 1,200,000 gallons a year, run time is 1,200,000 / 800 = 1,500 minutes, or 25 hours.
Printable worksheet: lagoon pump inspection log
- Pump make, model and serial number: ____________________
- Inspector and date: ____________ ; lockout done (yes or no): ______
- Tanker volume ______ gal / fill time ______ min = ______ gpm
- Measured flow ______ / rated flow ______ = ______ percent
- Hour meter reading ______ ; next service due at ______
- Leaks, noise, vibration or clogged screen: ____________
- Repair booked for (date): ______
Common mistakes
- Relying on the nameplate flow for hauling plans without ever timing a real fill.
- Servicing the pump with the power on or the line still pressurized.
- Ignoring a rise in vibration or noise because the pump is still moving liquid.
- Leaving the pump dry or full of solids over winter and finding the damage in spring.
Frequently asked questions
How often should I inspect the pump?
Check before each pumping season and briefly at the start of each job. Follow the manufacturer manual for interval details, and ask your dealer or service technician about the wear parts to check.
What does low flow usually mean?
A clogged screen, worn impeller, air leak, kinked hose or long suction lift can all cut flow. Work through the simple items first, with power locked out, and call a service technician if the cause is not obvious.
Is it safe to clear a plugged pump?
Only after shutting down and locking out the power or engine, and relieving pressure. Never reach into an intake or enter a pit, because manure gas and moving parts can kill. Call a trained service provider.
Official sources
Educational only. Permit, setback and application rules vary by state; confirm with your state agency, NRCS and a certified planner. State dairy waste resources.