Digestate Storage and Handling Plan
Digestate keeps coming whether or not the fields are fit to spread. This plan sizes storage from the days you cannot apply, adds rain and freeboard, and sets agitation, loadout and gas safety steps in order.
Why it matters
An undersized store forces spreading in bad weather, which is when runoff and violations happen. Sizing from your own calendar, not a guess, gives you a defensible number. Required days, design storm and freeboard are set by your state and engineer, so confirm all of them before building or relying on a store.
Step by step
- Count the days per year you cannot legally or safely apply, such as frozen ground, wet fields and crop cover, and add a contingency of several weeks.
- Multiply daily digestate volume by the holding days, adding milk house water, wash water and any outside feedstock that ends up in the store.
- For an open store, add rain falling on the surface above the design depth your engineer or agency sets, using surface area times depth.
- Add freeboard on top of the working depth, then divide the total volume by the volume per foot of depth to find the depth needed.
- Plan agitation with the tank manual, keeping people away during mixing, and set loadout so hoses, valves and pumps drain to a safe area.
- Post warning signs, keep covers and rails in place, and never enter a tank or pit; call emergency services for any gas or fall incident.
Worked example
Illustrative: Digestate flows at 4,000 gallons per day for 180 days of holding, so 180 x 4,000 = 720,000 gallons. An open store of 20,000 square feet takes an illustrative 6 inch rain, or 20,000 x 0.5 = 10,000 cubic feet, and 10,000 x 7.48 = 74,800 gallons. Total is 794,800 gallons. Each foot of depth holds 20,000 x 7.48 = 149,600 gallons, so depth is 794,800 / 149,600 = 5.3 feet, plus freeboard.
Printable worksheet: digestate storage plan
- Store name and surface area: ____________________ ______ sq ft
- Daily volume ______ gal x holding days ______ = ______ gallons
- Design rain ______ ft x area ______ sq ft x 7.48 = ______ gallons
- Total volume = flow + rain: ______ ; gallons per foot of depth = area x 7.48: ______
- Working depth = total / gallons per foot: ______ ft ; freeboard ______ in
- Agitation plan and people kept clear (yes or no): ______
- Signs, rails and covers checked on (date): ______
Common mistakes
- Sizing storage for the average year when a wet spring closes the fields for weeks.
- Forgetting wash water and rain, which add volume that never appears on the feed record.
- Standing near the tank during agitation, when gas can release in bursts.
- Planning loadout without a spill path, so a ruptured hose drains toward a ditch.
Frequently asked questions
How many days of storage do I need?
It depends on climate, crops and rules. Count your own unspreadable days, then ask your state agency, NRCS or engineer what minimum applies and what design storm to use.
Can I rely on a cover to cut rain volume?
A cover can change the rain you must store, but rules differ by state and design. Ask your engineer and agency whether credit is allowed before you count on a smaller tank.
Is digestate gas dangerous?
Yes. Hydrogen sulfide and other gases can reach harmful levels, especially while agitating or in low spaces. Keep out of tanks and pits, follow the manual, and call emergency services if someone collapses.
Official sources
Educational only. Permit, setback and application rules vary by state; confirm with your state agency, NRCS and a certified planner. State dairy waste resources.