Dairy Waste & Nutrient Management

Manure Gas Hazard Awareness Checklist

Stirring or pumping stored manure can release gas in seconds, and a pit that looked quiet an hour ago can kill. This checklist covers what to do before agitation, how to count air changes and what to do if someone collapses.

Why it matters

Most deaths come from a person entering to help someone else. Gas hazards cannot be seen, and smell is not a safe warning. Follow the equipment manual, the SDS and your safety program, call emergency services for any collapse, and never enter a pit or tank, even to rescue.

Step by step

  1. Schedule agitation for a time with wind and mild weather, tell everyone the start time, and move all animals and people out of the building before the pump starts.
  2. Open doors, curtains and all fans before agitation begins, and keep ventilation running until well after the pump stops and the surface settles.
  3. Set the work so no one stands over an opening, hatch or pipe while it is agitating, and keep hatches closed whenever not in use.
  4. Test and record each portable or fixed gas alarm against the maker schedule, and replace any unit that fails a test or passes its service date.
  5. Post a sign at every pit, tank and hatch stating no entry, and keep rescue ropes, phone and the emergency number within reach of the helper outside.
  6. Practice the collapse plan: call first, stay outside, shut off power at the pump, and let trained rescuers with breathing apparatus handle the space.

Worked example

Illustrative: A barn is 120 ft x 60 ft x 9 ft, so volume is 120 x 60 x 9 = 64,800 cubic feet. Fans run at 32,400 cubic feet per minute, giving 32,400 x 60 / 64,800 = 30 air changes per hour. A 600,000 gallon pit pumped at 1,500 gallons per minute takes 600,000 / 1,500 = 400 minutes, about 6 hours 40 minutes of agitation to keep clear of.

Printable worksheet: manure gas hazard awareness

  • Agitation date, start time and person in charge: ____________
  • Building volume: ______ x ______ x ______ = ______ cubic feet
  • Fan airflow ______ cfm x 60 / volume = ______ air changes per hour
  • Pit volume ______ gal / pump rate ______ gpm = ______ minutes
  • Everyone and all animals out at (time): ______
  • Alarm test date and result: ____________
  • Emergency number posted at pit (yes or no); drill date: ______

Common mistakes

  • Sending a second person into the pit after the first collapses, which turns one emergency into two.
  • Running agitation while animals are still inside because the schedule slipped by an hour.
  • Relying on smell as the warning, when some of the most dangerous gases stop being noticed.
  • Letting a failed alarm sit on a shelf until the next scheduled job because it was only a backup.

Frequently asked questions

Can I enter a pit if the fan is on?

No. Confined spaces need a trained team, atmospheric testing, rescue equipment and a written plan. A running fan is not enough. Call emergency services and a qualified contractor instead of improvising.

Do open lagoons carry the same risk?

Gas can still collect near agitation points, low spots and enclosed structures, though open surfaces vent more. Follow your plan, keep people away during agitation and ask your state safety program about site specific risks.

What should a helper do first?

Call emergency services, stay outside, and keep others away. Shut off power if it is safe to do so from outside. Do not enter to rescue. Give the dispatcher the address and tell them it is a manure gas event.

Official sources